IEC62133 Approved 451730 3.7V 210mAh Lithium Ion Polymer Battery
Source this high-capacity prismatic lithium battery from expert lithium ion battery manufacturers. Reliable power with IEC62133 and UN38.3 safety certification.
View productIf you are qualifying a wide temperature lithium battery for equipment that has to start in a cold field and keep working in summer heat, this guide turns the published numbers for the TWE0388 / HL18650V 18650 lithium battery into a selection decision you can defend to your thermal and safety reviewers.

Three passes are enough to go from a deployment brief to a cell shortlist. Work top to bottom and stop where your data runs out — that gap is exactly what the quote request should ask about.
Start with the highest and lowest temperature your device must actually survive while discharging. Compare that window with the published -40°C to 85°C discharge range before you look at any other number.
Match your run-time target to 2900mAh typical / 2800mAh minimum, then confirm the load profile stays inside the 10A maximum continuous discharge rating with headroom for peaks.
The product page publishes CC/CV charging with a 4.2V cutoff and lists IEC62133, UN38.3 and UL. It does not publish a charge temperature window, so lock that down with engineering before design freeze.
One published rating covers the whole window, so this table does not invent per-band derating. Each row tells you what the data supports today and what to confirm in writing.
| Operating band | What the published data supports | Continuous discharge | Charging caution | Recommended use |
|---|---|---|---|---|
| -40°C to -20°C | Inside the published -40°C to 85°C discharge window. Capacity is stated as 2900mAh typical / 2800mAh minimum for the cell; band-specific derating percentages are not published. | 10A max continuous — a single rating for the full window, not a cold derated figure | No charge temperature range published. Confirm cold-charge limits at RFQ. | Cold-start field instrumentation, winter-deployed sensors, remote GPS trackers |
| -20°C to 0°C | Inside the published discharge window. Cycle life is stated as more than 500 full charge-discharge cycles. | 10A max continuous | CC/CV to 4.2V cutoff; charge window to be confirmed at RFQ. | Outdoor monitoring nodes, overnight idle equipment, unheated enclosures |
| 0°C to 45°C | Comfortable middle of the published window. Internal resistance is stated as ≤18mΩ for pack-to-pack consistency. | 10A max continuous | Standard CC/CV charging with 4.2V cutoff as listed. | Rugged handhelds, IoT devices, vehicle-mounted devices |
| 45°C to 85°C | Upper end of the published discharge window — the differentiator for in-enclosure electronics and sun-exposed housings. | 10A max continuous | Heat raises charging risk; confirm the upper charge boundary at RFQ. | Automotive telemetry, outdoor energy storage, sealed roadside cabinets |
Item No. TWE0388 · Model HL18650V · 3.6V nominal · 2900mAh typical
The numbers your enclosure, protection circuit and thermal budget have to live with — exactly as published, with nothing extrapolated.
| Item No. / Model | TWE0388 / HL18650V |
| Nominal voltage | 3.6V |
| Typical capacity | 2900mAh |
| Minimum capacity | 2800mAh |
| Wide temperature range | -40°C to 85°C (discharge) |
| Max continuous discharge | 10A |
| Internal resistance | ≤18mΩ |
| Cycle life | >500 full charge-discharge cycles |
| Charge method / cutoff | Standard CC/CV · 4.2V |
| Certifications | IEC62133, UN38.3, UL |
| Manufacturing standards | ISO9001, ISO14001, BSCI |
| Customisation | OEM/ODM collaboration offered |
Before you fix the cell, check that the envelope and chemistry match how your product is built and serviced. Only the Topwell column carries published figures; the others are orientation notes to check with each supplier.
Trade-off: you accept 2900mAh-class capacity in exchange for the widest published window and a 10A continuous ceiling.
Trade-off: easier sourcing, but cold and heat limits usually force derating, heating or active thermal management.
Trade-off: more volume per cell and a different pack design for the sake of chemistry stability.
Trade-off: no rigid can, so mechanical support and protection electronics carry more of the design load.
Discharge is only half the story. The product page states standard CC/CV charging with a 4.2V cutoff — that defines the electrical protocol, not the temperature at which it is safe to apply it.
The failure mode to design around is cold charging, not cold discharging. Pushing charge current into a cold cell is where lithium plating risk appears, and it is the reason a battery that starts reliably at -30°C can still be damaged by an unmanaged charger the next morning.
Because the current product page does not publish a charge temperature range, treat this as an open item. Ask engineering for the charge window, the acceptable charge current below 0°C, and whether your charger should block or taper current in the cold. Apply the same discipline at the hot end of the window.
CC/CV charging to a 4.2V cutoff, as listed on the product page. Temperature limits for charging must be confirmed at RFQ.
These are the certification and manufacturing references listed for this cell. They tell your reviewer which standards the part is assessed against — request the current certificates alongside the quote.
The international safety standard for secondary cells and batteries. It is the reference most reviewers ask for when a cell goes into a portable or field-deployed device.
The transport test regime for lithium cells and batteries. It matters because your finished pack cannot ship by air or sea without it being addressed.
UL safety certification for lithium cells, commonly requested by North American customers and by end-product safety files.
Every deployment stresses a different number. Match your scenario to the specification that actually decides the design, then use the buyer action to close the gap before prototyping.
Same cell, different stress points: cold start for field nodes, heat endurance for sealed telemetry cabinets.
Six mechanical and electrical constraints to close out before the first prototype build.
Mechanical envelope, current ceiling and resistance budget are the three items that most often delay a build.
Tell us your deployment temperature window, load profile and annual volume. The team can return the datasheet, certification copies and a build proposal for your review.
review the product details, images, and specifications presented on the official product page.
use the application and use-case information published on the official product page.
confirm the specifications and options listed for the exact product variant before placing an order.
check the official product page or ask the supplier about options shown for the selected product.
use the official contact or inquiry path provided on the site.
include the product page, intended use, required quantity, and any specifications you need the supplier to review.